Enhanced & expandable multi-parameter patient monitor • 10.4" touch screen colour TFT LCD with 6 waveforms • individual sweep speed setting for each parameter • 168 full hours trend data are stored • SpO2 measurement with every low perfusion detection • screen freeze on/off • oxyCRG, drug calculation • external HDMI output for large screens • connection to central station using LAN or W-LAN (optional not included) • Li-ion battery with longer time life (3 hours of continuous operation) • real time bed to bed connectivity, max 8 monitors without server or central station • HL7 interface compatible •
it is possible to set all the wave and parameter colours, to identify anomalies related to specific diagnostic protocols
Enhanced & expandable multi-parameter patient monitor • 10.4" touch screen colour TFT LCD with 6 waveforms • individual sweep speed setting for each parameter • 168 full hours trend data are stored • SpO2 measurement with every low perfusion detection • screen freeze on/off • oxyCRG, drug calculation • external HDMI output for large screens • connection to central station using LAN or W-LAN (optional not included) • Li-ion battery with longer time life (3 hours of continuous operation) • real time bed to bed connectivity, max 8 monitors without server or central station • HL7 interface compatible •
it is possible to set all the wave and parameter colours, to identify anomalies related to specific diagnostic protocols
Temperature Unit (optional ) • Range: 0° to 50°C (32°F to 122°F) • Accuracy: ± 0.1°C (25 to 50°C), ± 0.2°C (0 to 24°C) • Compatible with: YSI Series 400 Temperature Probes
IBP - (option not included) • Channels: 2 • Measuring range: -50 to 300 mmHg • Measuring accuracy: ± 1 mmHg (<100 mmHg) ± 1 % of reading(>100 mmHg) • Pulse rate counting range: 0 to 300 beats/min • Zero balancing: range ± 200 mmHg accuracy ± 1 mmHg drift ± 1 mmHg over 24 hours • Transducer sensitivity: 5µV/V mmHg
Temperature Unit (optional ) • Range: 0° to 50°C (32°F to 122°F) • Accuracy: ± 0.1°C (25 to 50°C), ± 0.2°C (0 to 24°C) • Compatible with: YSI Series 400 Temperature Probes
IBP - (option not included) • Channels: 2 • Measuring range: -50 to 300 mmHg • Measuring accuracy: ± 1 mmHg (<100 mmHg) ± 1 % of reading(>100 mmHg) • Pulse rate counting range: 0 to 300 beats/min • Zero balancing: range ± 200 mmHg accuracy ± 1 mmHg drift ± 1 mmHg over 24 hours • Transducer sensitivity: 5µV/V mmHg
To provide a better browsing experience, proposing contents aligned with the user preferences, to customize our advertising contents and to allow interaction with social, this site uses Cookies, even of third parts. Clicking on "Accept" means accepting the use of all types of Cookie. Clicking on "Preferences" is possible to express our will related to the use of Cookies. For further information read the Cookie policy and the Privacy. Closing this banner you will reject all non strictly necessary cookies for this navigation session.