Riester RVS-100

multi-parameter monitor with printer - SpO2, NIBP

Riester RVS-100

multi-parameter monitor with printer - SpO2, NIBP

Code:
Brand:
Unit:
Availability:

2,595.96 £

(including VAT)

Price without VAT 2,472.34 £
info General information
assignment Technical information
work Standard equipment
list Compatible with

General information

Riester RVS-100 is a multi-parameter touch screen monitor for measuring pulse oximetry and blood pressure.
According to the needs of the healthcare system, it offers Spot-check, Triage and Monitor modes for all patients, from infants to adults.

Main features
  • 3 measurement modes (Monitor, Spot-check, Triage)
  • Highly responsive 8 ”color TFT touch screen with intuitive user interface and integrated help function
  • displays SYS, DIA, MAP, pulse, temperature, plethysmogram
  • EWS, NEWS and MEWS for early detection, which improves the outcome for patients
  • Clinical quality NIBP with averaging (2-5 readings) and neonate mode
  • Bluetooth connection to Riester 'tymPRO' and 'sensioPRO' thermometers
  • Riester Oximax SpO2, including newborn mode
  • connection to the electronic medical record (EMR) with the HL7 standard
  • LAN connection as standard
  • programmable alarms (audible, visual) with 3 priority levels
  • RJ11 port to ask for nursing assistance
  • internal memory for 5,000 measurements
  • Li-ion battery with 11 hours of autonomy (automatic mode, 15 min intervals)
  • intuitive user interface with highly responsive touch screen.
  • “Early Warning Scores” display mode.
  • programmable with EWS, NEWS, MEWS and 5 customizable profiles.

Standard equipment

  • Adult SpO2 sensor
  • SpO2 extension cable
  • NIBP extension tube
  • 2 cuffs (adult and large adult with connectors)
  • Manual (GB, IT. On request FR, DE, ES, RU)



Technical information

NIBP
  • Measurement method: automatic oscillometric
  • Measurement range:
  • Adults: [SYS 30-270 mmHg] [DIA 10-220 mmHg] [MAP 20-235 mmHg]
  • Children: [SYS 30-235 mmHg] [DIA 10-220 mmHg] [MAP 20-225 mmHg]
  • Neonates: [SYS 30-135 mmHg] [DIA 10-110 mmHg] [MAP 20-125 mmHg]
  • Cuff pressure range: 0-280mmHg, resolution 1mmHg
  • Pressure Accuracy: Static ± 3 mmHg / Clinical ± 5 mmHg, standard deviation = 8 mmHg
  • Pulse rate range: 40-240 bpm, 1 bpm accuracy
  • Initial inflation pressure: [Adults 160 mmHg] [Children 130 mmHg] [Infants 75 mmHg]
  • Double overpressure protection (hardware and software)
  • [Adults 297 ± 3 mmHg] [Children 252 ± 3 mmHg] [Infants 147 ± 3 mmHg]
  • Alarm range: SYS, DIA, MAP 0 - 300 mmHg

SpO2 Riester
  • Measurement range: 0-100%, resolution 1%
  • Accuracy: ± 2% (70-100%) - ± 3% (40-69%)
  • Unspecified (0-39%)
  • Alarm range: 0-100%
  • Average time: 4 sec, 8 sec, 16 sec
  • Heart rate
  • Measurement range: 20-250bpm, resolution 1bpm
  • Accuracy: ± 1% or ± 1 bpm, whichever is greater

Monitor
  • Alarm: Bright LEDs (red, yellow, cyan)
  • Voice messages
  • Audible alarm, QRS tone
  • It supports high tones and various volume levels
  • Alarm tones compliant with IEC 60601-1-8 requirements
  • Pressure: 45-85 dB test distance 1 meter from the tone

Doors:
  • 1 AC input
  • 1 standard RJ45 interface. 100 BASE-TX, IEEE 802.3
  • 4 USB ports
  • 1 equipotential grounding point
  • 1 RJ11 connector to ask for nursing assistance
  • 15V / 1.2A DC output port

General
  • Power supply: 100 - 240 V AC, 50/60 Hz
  • Battery: Li-ion, rechargeable, 10.8V VC, 6,600mAh
  • Full charge time: 6 hours
  • Operating time approx.11 hours (new and fully charged battery, with SpO2, Temp and NIBP modules in AUTO mode (interval 15 minutes))
  • Low battery and charging indicator
  • Monitor dimensions: 303×110× h 230 mm
  • Weight: 3600 g including printer
  • Riester code: 1960-RRXPE

Accessories